ENVIRONMENTAL TESTING CATALOG SM 4500-CN C, E
DCLS Method
Total cyanide
Reference Method
SM 4500-CN C, E
Test Description
Cyanide is converted to a gas and then to cyanogen chloride and measured spectrophotometrically.
Sample Collection
Collect aqueous samples in amber glass bottles. Samples should be de-chlorinated using Sodium Arsenite prior to collection and pH adjustment. Samples must be preserved with sodium hydroxide to pH 12 – 12.5.
Storage Guidelines
Store samples at 0 - 4 °C and analyze within 14 days.
Testing Group
Inorganics
Analyte
Cyanide